2026-09-09 Not graded 7 violation(s)
4.5.19.1.1 — Pool water depths are not clearly and permanently marked at the following locations: 1) Minimum depth, 2) Maximum depth, 3) On both sides and at each end of the pool and, 4) At the break in the floor slope between the shallow and deep portions of the pool.
Corrective action: Must correct by 10/10/26.
5.6.1.1.3 — Underwater lights, where provided, are not operational and/or maintained as designed.
Corrective action: Must correct by 12/10/26.
5.7.4.4.2 — The owner does not ensure the aquatic facility takes action to reduce the level of combined chlorine (chloramines) in the water when the level exceeds 0.4 ppm (mg/L).
Corrective action: Such actions may include but are not limited to: 1) superchlorination; 2) water exchange; or 3) patron adherence to appropriate bather hygiene practices. Must correct by 12/10/26.
5.9.1.6 — No Mixing - AQUATIC VENUE chemicals shall be stored so that if the packages were to leak, no mixing of incompatible materials would occur; observed liquid chemical storage over dry shock bags.
Corrective action: Must correct with proper storage by 12/10/26. 5.9.1.13 Separate - The CHEMICAL STORAGE SPACE shall be separate from the EQUIPMENT ROOM; Observed chlorine (shock and old tabs), miscellaneous pool chemical pails, extra muriatic acid, and other chemicals (cleaners) being stored in the mechanical room. Must correct by moving chemical storage area by 12/10/26.
5.7.5.3 — Observed test logs being conducted twice per day.
Corrective action: Must correct with 3 logs per 12 hour operational window by 12/10/26.
6.4.1.5 — A chemical inventory log is not maintained on site to provide a list of chemicals used in the aquatic venue water and surrounding deck that could result in water quality issues, chemical interactions, or patron exposure.
Corrective action: Must create inventory and correct by 12/10/26.
6.3.4.5.1 — A written EAP was not developed, maintained, and updated as necessary for the aquatic facility to include at a minimum: 1) A diagram of the aquatic facility; 2) A list of emergency telephone numbers; 3) The location of first aid kit and other rescue equipment (BVM, AED, if provided, backboard, etc.); 4) An emergency response plan for accidental chemical release; and 5) A fecal/vomit/blood contamination response plan as outlined in MAHC 6.5.1.; 6) Outline types of emergencies and imminent health hazards, as per MAHC 6.6.3; 7) Outline the methods of communication between responders, emergency services, and patrons; 8) Identify each anticipated responder; 9) Outline the tasks of each responder; 10) Identify required equipment for each task; and 11) Emergency closure requirements.
Corrective action: Must create Emergency Response and Communication plan by 12/10/26.
View official record on PDPHE portal →
Source: PDPHE, retrieved September 27, 2026.
2026-02-03 Not graded Violation details not available
Full violation detail for this inspection hasn't been retrieved yet.
View official record on PDPHE portal →
Source: PDPHE, retrieved September 27, 2026.
2025-09-29 Not graded Violation details not available
Full violation detail for this inspection hasn't been retrieved yet.
View official record on PDPHE portal →
Source: PDPHE, retrieved September 27, 2026.